← Wentworth Harbour Hotel
Edit in Desk ↗Foamy pour resolved — Roost at Wentworth Harbour Hotel
Resolvedcolin.bass@bantambarrel.demo · 2026-08-01 · ISS-QC-0010
Customer
Wentworth Harbour Hotel
New Castle, NH · owner: tess.okafor
Machine / asset
No machine linked
DisciplineDraft Lines
PriorityMedium
Spares statusNone
Last updated2026-08-10 15:33
Description
Wentworth Harbour Hotel reported Roost (batch 143) pouring roughly 80% foam at the bar. FOB flow control on that line was still set for the previous keg's higher carbonation level.
Work log
Currently: Shipped3 entries- CBcolin.bassShippedAug 10 · 03:33 PM
Confirmed clean pour on the follow-up visit. Closing.
- MWmarcus.whelanFixedAug 9 · 09:33 AM
Recalibrated for Roost's carbonation volumes and walked the bar staff through the pour-temp check.
- MWmarcus.whelanDiagnosedAug 1 · 09:33 PM
FOB was left at the previous product's carbonation setting after the last tap change.
Resolution
FOB flow-control component was left at the prior product's setting. Recalibrated for Roost's carbonation volumes and added a per-tap-change checklist item.
Actions
Move to
Classification