Keg washer fill sensor false 'full' reading aborts CIP cycle

Awaiting Customer

dana.cormier@bantambarrel.demo · 2026-08-07 07:33:30 · ISS-QC-0006

Edit in Desk ↗
Customer
No customer linked
Machine / asset
Keg Washer
serial KW-2020-02 · MACH-0006
DisciplinePackaging
PriorityHigh
Spares statusShipped
Last updated2026-08-13 23:33

Description

Sensor on keg washer station 2 reports 'full' mid-fill roughly one keg in twenty, which aborts the CIP cycle early and sends an under-cleaned keg downstream. Traced to the same inductive sensor picking up the adjacent valve body.

Work log

Currently: Waiting3 entries
  1. DCdana.cormierWaitingAug 13 · 11:33 PM

    Blocked on a maintenance window — next opening is after this week's packaging runs clear.

  2. DCdana.cormierShippedAug 11 · 09:33 PM

    Shielded replacement sensor ordered and shipped in.

  3. DCdana.cormierDiagnosedAug 7 · 05:33 PM

    Inductive sensor is picking up the adjacent valve body at the midpoint of the fill cycle.